Online spectrometer probes

CarboVis®/NiCaVis® System

  • In-situ measurement – fast response
  • No consumables
  • No ecologically harmful chemicals

in-situ measurement of Nitrate, COD, TOC, DOC, BOD or SAC (254 nm): High quality spectral measurement in a waterproof version for direct process control
Highly precise spectral measurement in a 40 mm (1.57 in.) in diameter sensor. Determination of measured values by spectral processing of the scanned UV/VIS spectrum. The TSS result is generally used for internal compensation. As an option the TSS value can be displayed as second parameter.

Features in detail:

  • The sensor measures directly in the process medium. No sample transport, no sample preparation necessary.
  • No lag-time between sampling and result of the measurement. Current values immediately available.
  • Extremely precise measurement due to the spectral analysis of the scanned UV/VIS range.
  • Very effective compensation of interferences and turbidity based on the spectral information – much better than a simple dual-beam measurement!
  • Long operation periods by automatic air cleaning – almost maintenance-free.
  • Optical system works without consumables
    -> low costs of ownership.

CarboVis® 700/5 IQ

Measuring Principle Spectral measurement in the UV/VIS range (200 - 750 nm)
Measuring Ranges
in Standard Solution
(potassium-hydrogenphtalate)
COD:
TOC:
SAC:
0.1 ... 800.0 mg/l
1 ... 500.0 mg/l
0.1 ... 600.0 1/m
Accuracy in Standard Solution ±3% of the measured value
±2.5 mg/l
(with Check algorithm)
Measuring Ranges TSS (Option) Inlet:
Effluent:
0 … 3000 mg/l TS
0.0 … 900.0 mg/l TS

CarboVis® 700/1 IQ

Measuring Principle Spectral measurement in the UV/VIS range (200 - 750 nm)
Measuring Ranges
in Standard Solution
(potassium-hydrogenphtalate)
COD:
TOC:
SAC:
0.5 … 4000.0 mg/l
5 … 2500.0 mg/l
0.5 … 3000.0 1/m
Accuracy in Standard Solution ±3% of the measured value
±2.5 mg/l
(with Check algorithm)
Measuring Ranges TSS (Option) Inlet:
Effluent:
0 … 15 g/l TS
0 … 4.5 g/l TS

NiCaVis® 700/5 IQ

Measuring Principle Spectral measurement in the UV/VIS range (200 - 750 nm)
Measuring Ranges
in Standard Solution
(potassium-hydrogenphtalate)
COD:
TOC:
SAC:
NO3-N:
0.1 ... 800.0 mg/l
1 ... 500.0 mg/l
0.1 ... 600.0 1/m
0.01 … 25.00 mg/l
Accuracy in Standard Solution ±3% of the measured value
±2.5 mg/l
(with Check algorithm)